CVE-2026-9400CWE-74CWE-77
Edimax BR-6675nD POST Request formUSBStorage command injection
Medium · published May 24, 2026
What it is
A flaw has been found in Edimax BR-6675nD 1.12. This issue affects the function formUSBStorage of the file /goform/formUSBStorage of the component POST Request Handler. Executing a manipulation of the argument sub_dir can lead to command injection. It is possible to launch the attack remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
The record
Technical detail
- CVSS v4.0
- 5.3 · MEDIUM
- Vector
- CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P
- EPSS
- 0.02378 · 83.8th percentile
- Weaknesses
- CWE-74 · Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'); CWE-77 · Improper Neutralization of Special Elements used in a Command ('Command Injection')
- Published
- 2026-05-24T22:00Z
EPSS history
Timeline