CVE-2026-50577CWE-323

CVE-2026-50577

High · published August 18, 2026

CVSS v3.1
7.4
EPSS
1%
Percentile
42.9
In the wild
Unconfirmed
What it is

ePA 3.x Integration implements the authorization workflow and writes Medical Information Objects to Germany's electronic patient record. Prior to 1.3.0, ePA 3.x Integration leaves request_counter unchanged in app/vau/VAUProtokoll.py while constructing VAU messages. The frozen client request counter causes the server side to reuse AES-GCM nonce and key combinations across responses. A network attacker who collects repeated ciphertexts can recover the XOR of plaintexts and use predictable inner HTTP headers and JSON fields to recover sensitive data, including patient health records. Repeated nonces can also enable recovery of the GHASH authentication key through the Joux forbidden attack, allowing forged AES-GCM messages and injection of malicious responses. The response-counter check also fails to maintain last_response_counter, weakening replay and ordering validation. This issue is fixed in version 1.3.0.

The record
Technical detail
CVSS v3.1
7.4 · HIGH
Vector
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N
CVSS v4.0
Not supplied
EPSS
0.00513 · 42.9th percentile
Weakness
CWE-323 · Reusing a Nonce, Key Pair in Encryption
Published
2026-08-18T21:16Z
References (5)
EPSS history
Timeline
  • 18 AUG 16:52Z
    ePA 3.x Integration: AES-GCM Nonce Reuse via Frozen VAU Request Counter
    cvelistv5