CVE-2026-16938CWE-862broken-access-control

CVE-2026-16938

Medium · published August 19, 2026

CVSS v3.1
6.9
EPSS
0%
Percentile
12.4
In the wild
Unconfirmed
What it is

IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in access controls over privileged system configuration operations on the FSP. An attacker with authenticated administrator-level access to the FSP can place the managed system into a non-production operational mode, allowing certain system components to be disabled. This condition persists across FSP resets and requires explicit operator intervention — clearing the affected configuration — to restore normal operation. Successful exploitation results in an availability impact to the managed system.

The record
Technical detail
CVSS v3.1
6.9 · MEDIUM
Vector
CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:H
CVSS v4.0
Not supplied
EPSS
0.00225 · 12.4th percentile
Weakness
CWE-862 · Missing Authorization
Published
2026-08-19T23:17Z
Affected products (10)
ProductVersionsFixed in
ibm/power_system_e1080_\(9080-hex\)_firmware≥ fw1060.00, < fw1060.81fw1060.81
ibm/power_system_e1180_\(9080-heu\)_firmware≥ fw1110.00, < fw1110.31fw1110.31
ibm/power_system_e1180_\(9080-heu\)_firmwareall versions—
ibm/power_system_s922_\(9009-22g\)_firmware≥ fw950.00, < fw950.h3fw950.h3
ibm/power_system_h922_\(9223-22s\)_firmware≥ fw950.00, < fw950.h3fw950.h3
ibm/power_system_s914_\(9009-41g\)_firmware≥ fw950.00, < fw950.h3fw950.h3
ibm/power_system_s924_\(9009-42g\)_firmware≥ fw950.00, < fw950.h3fw950.h3
ibm/power_system_h924_\(9223-42s\)_firmware≥ fw950.00, < fw950.h3fw950.h3
ibm/power_system_e950_\(9040-mr9\)_firmware≥ fw950.00, < fw950.h3fw950.h3
ibm/power_system_e980_\(9080-m9s\)_firmware≥ fw950.00, < fw950.h3fw950.h3
References (1)
EPSS history
Timeline
  • 19 AUG 18:48Z
    Power System Missing Authorization
    cvelistv5