CVE-2026-111215CWE-78command-injection

CVE-2026-111215

High · published October 15, 2026

CVSS v3.1
7.2
EPSS
6%
Percentile
93.4
In the wild
Unconfirmed
What it is

Netgate pfSense CE through 2.9.0 contains an OS command injection vulnerability that allows authenticated users to execute commands as root by supplying a crafted wireless parent interface name. Attackers with limited Wireless Edit or Interface Assignments privileges can submit values like ath0;<cmd> via interfaces_wireless_edit.php or interfaces_assign.php, which interface_wireless_clone() interpolates unescaped into an ifconfig shell command.

The record
Technical detail
CVSS v3.1
7.2 · HIGH
Vector
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
CVSS v4.0
8.6 · CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
EPSS
0.06123 · 93.4th percentile
Weakness
CWE-78 · Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Published
2026-10-15T23:17Z
Affected products (1)
ProductVersionsFixed in
pfsense/pfsense≤ 2.9.0—
References (7)
EPSS history
Timeline
  • 17 OCT 03:28Z
    EPSS moved — → 7%
    epss
  • 15 OCT 18:46Z
    Netgate pfSense CE through 2.9.0 OS Command Injection via Wireless Parent Interface
    cvelistv5
  • 15 OCT 18:46Z
    Netgate pfSense CE through 2.9.0 OS Command Injection via Wireless Parent Interface
    cvelistv5