CVE-2025-8821CWE-77CWE-78
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasic os command injection
Medium · published August 11, 2025
What it is
A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This issue affects the function RP_setBasic of the file /goform/RP_setBasic. The manipulation of the argument bssid leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
The record
Technical detail
- CVSS v4.0
- 5.3 · MEDIUM
- Vector
- CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P
- EPSS
- 0.06814 · 94.0th percentile
- Weaknesses
- CWE-77 · Improper Neutralization of Special Elements used in a Command ('Command Injection'); CWE-78 · Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
- Published
- 2025-08-11T00:02Z
EPSS history
Timeline