CVE-2025-2717CWE-77CWE-78

D-Link DIR-823X HTTP POST Request diag_nslookup sub_41710C os command injection

Medium · published March 24, 2025

CVSS v4.0
5.1
EPSS
5%
Percentile
91.7
In the wild
Unconfirmed
What it is

A vulnerability, which was classified as critical, has been found in D-Link DIR-823X 240126/240802. This issue affects the function sub_41710C of the file /goform/diag_nslookup of the component HTTP POST Request Handler. The manipulation of the argument target_addr leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

The record
Technical detail
CVSS v4.0
5.1 · MEDIUM
Vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N
EPSS
0.04623 · 91.7th percentile
Weaknesses
CWE-77 · Improper Neutralization of Special Elements used in a Command ('Command Injection'); CWE-78 · Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Published
2025-03-24T23:31Z
EPSS history