CVE-2025-22961

A critical information disclosure vulnerability exists in the web-based management interface of GatesAir Maxiva UAXT, VAXT transmitters due to Incorrect Access…

High · published February 13, 2025

CVSS v3.1
8.0
EPSS
0%
Percentile
32.6
In the wild
Unconfirmed
What it is

A critical information disclosure vulnerability exists in the web-based management interface of GatesAir Maxiva UAXT, VAXT transmitters due to Incorrect Access Control (CWE-284). Unauthenticated attackers can directly access sensitive database backup files (snapshot_users.db) via publicly exposed URLs (/logs/devcfg/snapshot/ and /logs/devcfg/user/). Exploiting this vulnerability allows retrieval of sensitive user data, including login credentials, potentially leading to full system compromise.

The record
Technical detail
CVSS v3.1
8.0 · HIGH
Vector
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
CVSS v4.0
Not supplied
EPSS
0.00396 · 32.6th percentile
Published
2025-02-13T00:00Z
EPSS history
Timeline
  • 13 FEB 00:00Z
    A critical information disclosure vulnerability exists in the web-based management interface of GatesAir Maxiva UAXT, VAXT transmitters due to Incorrect Access…