CVE-2024-48966CWE-306

Life2000 service tools for test and calibration do not support user authentication

Critical · published November 14, 2024

CVSS v3.1
10.0
EPSS
1%
Percentile
52.5
In the wild
Unconfirmed
What it is

🚨 Unrestricted access to service tools on ventilators? That’s a recipe for disaster! 🔥 Think of it as a hospital's maintenance crew having the keys to all the ventilation systems without any ID check — they could inadvertently or maliciously tweak settings or access sensitive data, putting patient lives at risk. Just like any oversight in a surgery can be devastating, this flaw leaves the ventilator's safety wide open. An attacker with physical access to the service PC can manipulate ventilator settings or leak sensitive data, leading to potentially catastrophic patient safety issues. This isn't just a minor oversight; it could compromise device performance and result in unauthorized information disclosure. The stakes are incredibly high, and the implications could be absolutely devastating for patients relying on these devices!

Put simply

Think of it as a hospital's maintenance crew having the keys to all the ventilation systems without any ID check — they could inadvertently or maliciously tweak settings or access sensitive data, putting patient lives at risk. Just like any oversight in a surgery can be devastating, this flaw leaves the ventilator's safety wide open. This vulnerability stems from the lack of user authentication in the software tools used for ventilator calibration and diagnostics, allowing unauthorized users to access and modify settings without any checks.

What to do

An attacker with physical access to the service PC can manipulate ventilator settings or leak sensitive data, leading to potentially catastrophic patient safety issues. This isn't just a minor oversight; it could compromise device performance and result in unauthorized information disclosure. The stakes are incredibly high, and the implications could be absolutely devastating for patients relying on these devices! Immediately enforce user authentication for all calibration and diagnostic tools related to ventilators. Conduct a thorough security review of the service PC's access controls and consider updating the software to include robust authentication measures. You've got this! Secure those tools and keep patient safety a top priority! 🛡️

The record
Technical detail
CVSS v3.1
10.0 · CRITICAL
Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
CVSS v4.0
Not supplied
EPSS
0.00695 · 52.5th percentile
Weakness
CWE-306 · Missing Authentication for Critical Function
Published
2024-11-14T21:38Z
EPSS history
Timeline
  • 14 NOV 21:38Z
    Life2000 service tools for test and calibration do not support user authentication
    cvelistv5