CVE-2024-2809CWE-121

Tenda AC15 SetFirewallCfg formSetFirewallCfg stack-based overflow

High · published March 22, 2024

CVSS v3.1
8.8
EPSS
2%
Percentile
79.7
In the wild
Unconfirmed
What it is

A vulnerability, which was classified as critical, was found in Tenda AC15 15.03.05.18/15.03.20_multi. Affected is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257664. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

The record
Technical detail
CVSS v3.1
8.8 · HIGH
Vector
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CVSS v4.0
Not supplied
EPSS
0.01918 · 79.7th percentile
Weakness
CWE-121 · Stack-based Buffer Overflow
Published
2024-03-22T05:31Z
EPSS history
Timeline
  • 22 MAR 05:31Z
    Tenda AC15 SetFirewallCfg formSetFirewallCfg stack-based overflow
    cvelistv5