FLIR AX8 thermal sensor cameras up to and including 1.46.16 are vulnerable to Directory Traversal due to improper access restriction

High · published January 10, 2024

CVSS v3.1
7.5
EPSS
1%
Percentile
69.2
In the wild
Unconfirmed
What it is

FLIR AX8 thermal sensor cameras up to and including 1.46.16 are vulnerable to Directory Traversal due to improper access restriction. This vulnerability allows an unauthenticated, remote attacker to obtain arbitrary sensitive file contents by uploading a specially crafted symbolic link file. NOTE: The vendor has stated that with the introduction of firmware version 1.49.16 (Jan 2023) the FLIR AX8 should no longer be affected by the vulnerability reported. Latest firmware version (as of Oct 2025, was released Jun 2024) is 1.55.16.

The record
Technical detail
CVSS v3.1
7.5 · HIGH
Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
CVSS v4.0
Not supplied
EPSS
0.01254 · 69.2th percentile
Published
2024-01-10T00:00Z
EPSS history
Timeline
  • 10 JAN 00:00Z
    FLIR AX8 thermal sensor cameras up to and including 1.46.16 are vulnerable to Directory Traversal due to improper access restriction