CVE-2022-48942

hwmon: Handle failure to register sensor with thermal zone correctly

published August 22, 2024

CVSS
—
EPSS
0%
Percentile
11.1
In the wild
Unconfirmed
What it is

In the Linux kernel, the following vulnerability has been resolved:

hwmon: Handle failure to register sensor with thermal zone correctly

If an attempt is made to a sensor with a thermal zone and it fails,

the call to devm_thermal_zone_of_sensor_register() may return -ENODEV.

This may result in crashes similar to the following.

Unable to handle kernel NULL pointer dereference at virtual address 00000000000003cd

...

Internal error: Oops: 96000021 [#1] PREEMPT SMP

...

pstate: 60400009 (nZCv daif +PAN -UAO -TCO -DIT -SSBS BTYPE=--)

pc : mutex_lock+0x18/0x60

lr : thermal_zone_device_update+0x40/0x2e0

sp : ffff800014c4fc60

x29: ffff800014c4fc60 x28: ffff365ee3f6e000 x27: ffffdde218426790

x26: ffff365ee3f6e000 x25: 0000000000000000 x24: ffff365ee3f6e000

x23: ffffdde218426870 x22: ffff365ee3f6e000 x21: 00000000000003cd

x20: ffff365ee8bf3308 x19: ffffffffffffffed x18: 0000000000000000

x17: ffffdde21842689c x16: ffffdde1cb7a0b7c x15: 0000000000000040

x14: ffffdde21a4889a0 x13: 0000000000000228 x12: 0000000000000000

x11: 0000000000000000 x10: 0000000000000000 x9 : 0000000000000000

x8 : 0000000001120000 x7 : 0000000000000001 x6 : 0000000000000000

x5 : 0068000878e20f07 x4 : 0000000000000000 x3 : 00000000000003cd

x2 : ffff365ee3f6e000 x1 : 0000000000000000 x0 : 00000000000003cd

Call trace:

mutex_lock+0x18/0x60

hwmon_notify_event+0xfc/0x110

0xffffdde1cb7a0a90

0xffffdde1cb7a0b7c

irq_thread_fn+0x2c/0xa0

irq_thread+0x134/0x240

kthread+0x178/0x190

ret_from_fork+0x10/0x20

Code: d503201f d503201f d2800001 aa0103e4 (c8e47c02)

Jon Hunter reports that the exact call sequence is:

hwmon_notify_event()

--> hwmon_thermal_notify()

--> thermal_zone_device_update()

--> update_temperature()

--> mutex_lock()

The hwmon core needs to handle all errors returned from calls

to devm_thermal_zone_of_sensor_register(). If the call fails

with -ENODEV, report that the sensor was not attached to a

thermal zone but continue to register the hwmon device.