CVE-2022-46670CWE-79

Rockwell Automation MicroLogix 1100 & 1400 Vulnerable to Cross-Site Scripting Attack

High · published December 16, 2022

CVSS v3.1
7.1
EPSS
1%
Percentile
47.1
In the wild
Unconfirmed
What it is

Rockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution.  The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website.

The record
Technical detail
CVSS v3.1
7.1 · HIGH
Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L
CVSS v4.0
Not supplied
EPSS
0.00582 · 47.1th percentile
Weakness
CWE-79 · Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Published
2022-12-16T20:12Z
EPSS history
Timeline
  • 16 DEC 20:12Z
    Rockwell Automation MicroLogix 1100 & 1400 Vulnerable to Cross-Site Scripting Attack
    cvelistv5