CVE-2022-43110

Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web…

Critical · published August 22, 2025

CVSS v3.1
9.8
EPSS
1%
Percentile
51.0
In the wild
Unconfirmed
What it is

🚨 A remote attacker can hijack the entire Voltronic Power system with zero authentication! Imagine someone who can just stroll in and change the admin password without breaking a sweat. 🔥 Think of it like a hotel where anyone can simply walk behind the front desk and start changing reservations and accessing customers' sensitive information, all without ever checking in. This vulnerability allows an attacker to gain full control over the system, potentially leading to the shutdown of connected UPS devices, alteration of critical settings, and viewing sensitive configuration details. It's an absolute nightmare for anyone relying on these systems to maintain power. An attacker could wreak havoc and disrupt operations at any moment!

Put simply

Think of it like a hotel where anyone can simply walk behind the front desk and start changing reservations and accessing customers' sensitive information, all without ever checking in. The flaw in Voltronic Power's web interface permits unauthorized remote configuration changes, enabling attackers to modify settings, reset admin passwords, and manage connected UPS devices—all without requiring any form of authentication.

What to do

This vulnerability allows an attacker to gain full control over the system, potentially leading to the shutdown of connected UPS devices, alteration of critical settings, and viewing sensitive configuration details. It's an absolute nightmare for anyone relying on these systems to maintain power. An attacker could wreak havoc and disrupt operations at any moment! To protect against this critical vulnerability, upgrade to Power ViewPower version 1.04-23292 or later. Additionally, ensure that any exposure of the web interface is tightly controlled, possibly by implementing IP whitelisting or VPN requirements for access. Don't delay—secure your system today! You've got this! With the right steps, you can lock down your systems and keep the attackers at bay! 🛡️

The record
Technical detail
CVSS v3.1
9.8 · CRITICAL
Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS v4.0
Not supplied
EPSS
0.00660 · 51.0th percentile
Published
2025-08-22T00:00Z
EPSS history
Timeline
  • 22 AUG 00:00Z
    Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web…
    cvelistv5