CVE-2022-0902CWE-22CWE-77
ABB Flow Computer and Remote Controllers Path Traversal Vulnerability in Totalflow TCP protocol can lead to root access
High · published July 21, 2022
What it is
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in flow computer and remote controller products of ABB ( RMC-100 (Standard), RMC-100-LITE, XIO, XFCG5 , XRCG5 , uFLOG5 , UDC) allows an attacker who successfully exploited this vulnerability could insert and run arbitrary code in an affected system node.
The record
Technical detail
- CVSS v3.1
- 8.1 · HIGH
- Vector
- CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
- CVSS v4.0
- Not supplied
- EPSS
- 0.16918 · 97.1th percentile
- Weaknesses
- CWE-22 · Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'); CWE-77 · Improper Neutralization of Special Elements used in a Command ('Command Injection')
- Published
- 2022-07-21T15:34Z
EPSS history
Timeline