CVE-2021-43283

An issue was discovered on Victure WR1200 devices through 1.0.3

published November 30, 2021

CVSS
—
EPSS
5%
Percentile
91.6
In the wild
Unconfirmed
What it is

An issue was discovered on Victure WR1200 devices through 1.0.3. A command injection vulnerability was found within the web interface of the device, allowing an attacker with valid credentials to inject arbitrary shell commands to be executed by the device with root privileges. This occurs in the ping and traceroute features. An attacker would thus be able to use this vulnerability to open a reverse shell on the device with root privileges.

The record
Technical detail
CVSS
Not scored
CVSS v4.0
Not supplied
EPSS
0.04566 · 91.6th percentile
Published
2021-11-30T18:22Z
EPSS history
Timeline
  • 30 NOV 18:22Z
    An issue was discovered on Victure WR1200 devices through 1.0.3
    cvelistv5