CVE-2021-1586CWE-345

Cisco Nexus 9000 Series Fabric Switches ACI Mode Multi-Pod and Multi-Site TCP Denial of Service Vulnerability

High · published August 25, 2021

CVSS v3.1
8.6
EPSS
2%
Percentile
84.3
In the wild
Unconfirmed
What it is

A vulnerability in the Multi-Pod or Multi-Site network configurations for Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an unauthenticated, remote attacker to unexpectedly restart the device, resulting in a denial of service (DoS) condition. This vulnerability exists because TCP traffic sent to a specific port on an affected device is not properly sanitized. An attacker could exploit this vulnerability by sending crafted TCP data to a specific port that is listening on a public-facing IP address for the Multi-Pod or Multi-Site configuration. A successful exploit could allow the attacker to cause the device to restart unexpectedly, resulting in a DoS condition.

The record
Technical detail
CVSS v3.1
8.6 · HIGH
Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H
CVSS v4.0
Not supplied
EPSS
0.02453 · 84.3th percentile
Weakness
CWE-345 · Insufficient Verification of Data Authenticity
Published
2021-08-25T19:10Z
EPSS history
Timeline
  • 25 AUG 19:10Z
    Cisco Nexus 9000 Series Fabric Switches ACI Mode Multi-Pod and Multi-Site TCP Denial of Service Vulnerability