CVE-2021-0203CWE-794

Junos OS: EX and QFX5K Series: Storm Control does not work as expected when Redundant Trunk Group is configured

High · published January 15, 2021

CVSS v3.1
8.6
EPSS
1%
Percentile
60.6
In the wild
Unconfirmed
What it is

On Juniper Networks EX and QFX5K Series platforms configured with Redundant Trunk Group (RTG), Storm Control profile applied on the RTG interface might not take affect when it reaches the threshold condition. Storm Control enables the device to monitor traffic levels and to drop broadcast, multicast, and unknown unicast packets when a specified traffic level is exceeded, thus preventing packets from proliferating and degrading the LAN. Note: this issue does not affect EX2200, EX3300, EX4200, and EX9200 Series. This issue affects Juniper Networks Junos OS on EX Series and QFX5K Series: 15.1 versions prior to 15.1R7-S7; 16.1 versions prior to 16.1R7-S8; 17.2 versions prior to 17.2R3-S4; 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R2-S11, 17.4R3-S2; 18.1 versions prior to 18.1R3-S10; 18.2 versions prior to 18.2R3-S5; 18.3 versions prior to 18.3R2-S4, 18.3R3-S2; 18.4 versions prior to 18.4R2-S5, 18.4R3-S3; 19.1 versions prior to 19.1R2-S2, 19.1R3-S2; 19.2 versions prior to 19.2R1-S5, 19.2R2-S1, 19.2R3; 19.3 versions prior to 19.3R2-S4, 19.3R3; 19.4 versions prior to 19.4R1-S3, 19.4R2-S1, 19.4R3; 20.1 versions prior to 20.1R1-S2, 20.1R2.

The record
Technical detail
CVSS v3.1
8.6 · HIGH
Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H
CVSS v4.0
Not supplied
EPSS
0.01002 · 60.6th percentile
Weakness
CWE-794 · Incomplete Filtering of Multiple Instances of Special Elements
Published
2021-01-15T17:35Z
EPSS history
Timeline
  • 15 JAN 17:35Z
    Junos OS: EX and QFX5K Series: Storm Control does not work as expected when Redundant Trunk Group is configured
    cvelistv5