CVE-2020-15782CWE-119

A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl

Critical · published May 28, 2021

CVSS v3.1
9.8
EPSS
5%
Percentile
92.4
In the wild
Unconfirmed
What it is

🚨 A simple network access on port 102/tcp unlocks a path into the critical SIMATIC Drive Controller family — making it alarmingly easy for an attacker to write or read data! 🔥 Think of it like a chef being handed a spare key to the kitchen without a thorough background check. Once they’re in, they can sneak in unwanted ingredients or even change the recipe entirely, putting everyone at risk! An attacker could waltz right into the system and alter configurations, inject malicious code, or pilfer sensitive data — all without needing any authentication! This vulnerability could lead to catastrophic operational failures, data breaches, and potentially compromise entire automation systems.

Put simply

Think of it like a chef being handed a spare key to the kitchen without a thorough background check. Once they’re in, they can sneak in unwanted ingredients or even change the recipe entirely, putting everyone at risk! This vulnerability allows remote unauthenticated attackers to bypass memory protection on affected SIMATIC devices through a specific operation, enabling them to manipulate protected memory areas or access critical data.

What to do

An attacker could waltz right into the system and alter configurations, inject malicious code, or pilfer sensitive data — all without needing any authentication! This vulnerability could lead to catastrophic operational failures, data breaches, and potentially compromise entire automation systems. Immediate action is crucial! Upgrade affected devices to the latest versions: SIMATIC Drive Controllers to V2.9.2 or higher, and for others, ensure S7-1200 to V4.5.0, S7-1500 and related CPUs to V2.9.2, and so on. Regularly audit your network to monitor access to port 102/tcp. You’ve got this! Follow the patching steps and bolster your defenses — keep your systems safe! 🛡️

The record
Technical detail
CVSS v3.1
9.8 · CRITICAL
Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS v4.0
Not supplied
EPSS
0.05184 · 92.4th percentile
Weakness
CWE-119 · Improper Restriction of Operations within the Bounds of a Memory Buffer
Published
2021-05-28T16:10Z
EPSS history
Timeline
  • 28 MAY 16:10Z
    A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl
    cvelistv5